O. Reg. 597/99
ONTARIO REGULATION 597/99
made under the
BUILDING CODE ACT, 1992
Filed: December 15, 1999
Amending O. Reg 403/97
(The Building Code)
Note: Since the end of 1998, Ontario Regulation 403/97 has been amended by Ontario Regulations 152/99, 278/99 and 593/99. Previous amendments are listed in the Table of Regulations in the Statutes of Ontario, 1998.
- Section 9.5 of Ontario Regulation 403/97 is amended by adding the following Subsection:
9.5.7A. Combined Spaces
9.5.7A.1. Combined Living, Dining, Bedroom and Kitchen Spaces
(1) Despite Subsections 9.5.4, 9.5.5, 9.5.6 and 9.5.7, where living, dining, bedroom and kitchen spaces are combined in a dwelling unit that contains sleeping accommodation for not more than 2 persons, the area of the combined spaces shall be not less than 13.5m2.
This document is prepared for purposes of convenience only, and for accurate reference recourse should be had to the Official Volumes.