CATEGORY |
CHANGE
NUMBER |
DESCRIPTION |
|
Residential
Sprinklers |
A-01-04-01 |
Revise the definition of live/work unit Clause 1.4.1.2.(1)(b) of Division A. |
|
B-03-01-01 |
Remove the 6 storey height limitation for sprinklered buildings with combustible wall components conforming to Sentence 3.1.5.5.(1) of Division B. |
|
B-03-01-02 |
Delete the requirement that firewalls in buildings regulated by the provisions of Subsection 3.2.6. be constructed of masonry or concrete. |
|
B-03-02-01 |
Mandate the installation of fire sprinklers in multiple-unit residential buildings over three storeys in height in Articles 3.2.2.42. and 3.2.2.43. of Division B. |
|
B-03-02-02 |
Permit unsprinklered 2-storey stacked townhouses of noncombustible construction in buildings up to 4 storeys in height. |
|
B-03-02-03 |
Harmonize the requirements of Subsection 3.2.6. of Division B with the model National Building Code. |
|
B-03-03-01 |
Harmonize the provisions for fire separations around multi level dwelling units in Sentence 3.3.4.2.(3) of Division B with the model National Building Code. |
|
B-03-03-02 |
Require separated means of egress from each dwelling unit in 2-storey stacked townhouses of noncombustible construction in unsprinklered buildings up to 4 storeys in height. |
|
B-11-04-01 |
Define reduction in performance level resulting from a to change in major occupancy to a Group C occupancy. |
|
B-11-04-02 |
Mandate the installation of fire sprinklers in a storey subject to a change in major occupancy to a Group C occupancy in existing buildings. |
|
Sewage System
Area Beds |
A-01-04-02 |
Add new definition of “Area Bed” to Clause 1.4.1.2.(1)(b) of Division A. |
|
B-08-06-01 |
Revise existing Sentence 8.6.2.2.(2) of Division B to regulate the effluent from treatment units discharging to area beds. |
|
B-08-07-01 |
Provide requirements for area beds by adding a new Subsection 8.7.7. “Area Bed” in Division B. |
|
B-08-09-01 |
Editorial - Revise title of Article 8.9.2.4. of Division B to include area beds. |
|
Sewage Systems
Reinspection |
C-01-03-01 |
Editorial - Orders |
|
C-01-10-01 |
Add new Subsection 1.10., Sewage System Maintenance Programs, in Division C. |
|
C-03-01-01 |
Add qualifications for persons carrying out sewage system maintenance inspections. |
|
C-03-01-02 |
Editorial - Qualifications for sewage system maintenance program inspectors. |